Calculating drain diameter

 
Post new topic   Reply to topic    Downsizer Forum Index -> Land Management
Author 
 Message
Mutton



Joined: 09 May 2009
Posts: 1508

PostPosted: Sun Jul 31, 11 8:19 pm    Post subject: Calculating drain diameter Reply with quote
    

Does anyone know of a good formula or website with advice regarding diameter of a drain pipe. I mean the sort you lay in the ground, not the sort from gutters. It will be taking run-off from the house roof plus from the slope above the house and the patio. We were thinking it needed to be fairly generous so that it doesn't block easily with any crud washed into it or silt build up.

stumbling goat



Joined: 20 Jan 2009
Posts: 1990

PostPosted: Sun Jul 31, 11 9:23 pm    Post subject: Reply with quote
    

Building regs used to say underground drainage will need to be 150mm, usually in a bed of pea shingle gravel, with a minimum fall over a distance and if to a soakaway, then that soakaway has to be a mimimum distance from any footings or buildings. I think it is 3 meters, hmm, maybe even 5.

Check building regs, for although they may not be enforceable for what you are doing, if you came to sell compliance would be good.

Please check though, I have not had to lay a drain for some time or dig a soakaway.

sg

Ty Gwyn



Joined: 22 Sep 2010
Posts: 4567
Location: Lampeter
PostPosted: Sun Jul 31, 11 10:55 pm    Post subject: Reply with quote
    

Underground soil pipes are 4in,as are normal drain gulleys.

Strange thing is,a smaller diameter pipe layed at the correct fall,has less tendency to silt up,because water flows through under greater pressure,keeping pipe clean.

onemanband



Joined: 26 Dec 2010
Posts: 1473
Location: NCA90
PostPosted: Mon Aug 01, 11 12:22 am    Post subject: Reply with quote
    

Most houses function fine on 4inch pipe
150mm/6 inch is only used on public sewers and large commercial.
Chudley construction handbook says 4inch will serve upto 20 dwellings. So unless you have a large mansion and several acres to drain 4 inch will be sufficient.
Also 4inch pipe and fittings are more readily available than 6inch and far cheaper.
If worried about silt/crud fit traps/ interceptors at bottom of downpipes and where surface water enters system.
Crud doesn't cause blockages - but badly laid drains will.

Tavascarow



Joined: 06 Aug 2006
Posts: 8407
Location: South Cornwall
PostPosted: Mon Aug 01, 11 7:07 am    Post subject: Reply with quote
    

With regards to the fall IIRC the optimum is 1 in 50.
& I agree with the others 4" pipe will be fine.

Mutton



Joined: 09 May 2009
Posts: 1508

PostPosted: Mon Aug 01, 11 8:31 am    Post subject: Reply with quote
    

Thank you. That's all very helpful.

Mutton



Joined: 09 May 2009
Posts: 1508

PostPosted: Wed Aug 03, 11 1:40 pm    Post subject: Reply with quote
    

stumbling goat wrote:
Building regs used to say underground drainage will need to be 150mm, usually in a bed of pea shingle gravel,

sg


By the way, does anyone know why the bed of pea shingle gravel? Also, is it necessary if there will be no vehicles driving over the drain pipe?

jamanda
Downsizer Moderator


Joined: 22 Oct 2006
Posts: 35056
Location: Devon
PostPosted: Wed Aug 03, 11 1:43 pm    Post subject: Reply with quote
    

I'd bump this when Behemoth is in the house. It's right up his street.

Behemoth



Joined: 01 Dec 2004
Posts: 19023
Location: Leeds
PostPosted: Wed Aug 03, 11 5:24 pm    Post subject: Reply with quote
    

Can't add much to what's been said.

Behemoth



Joined: 01 Dec 2004
Posts: 19023
Location: Leeds
PostPosted: Thu Aug 04, 11 5:09 pm    Post subject: Reply with quote
    

Apart from the peas shingle is to ensure the pipe is well bedded and doesn't flex when under load (full of water), moving joints/deformation etc. I think.

onemanband



Joined: 26 Dec 2010
Posts: 1473
Location: NCA90
PostPosted: Fri Aug 05, 11 11:00 pm    Post subject: Reply with quote
    

Mutton wrote:
stumbling goat wrote:
Building regs used to say underground drainage will need to be 150mm, usually in a bed of pea shingle gravel,

sg


By the way, does anyone know why the bed of pea shingle gravel? Also, is it necessary if there will be no vehicles driving over the drain pipe?


Several reasons;
Any ground movement/settlement will be taken up by the shingle so pipe will be less likely to move
shingle fills around the pipe easily and fully so reduces chances of settlement later on - and also makes backfilling easier.
shingle will also protect pipes from damage in stoney/rubbley ground
And it also makes pipes easier to find and repair

If pipe is going to be driven over - it should have a 6inch concrete capping (ontop of shingle) to prevent damage by point loads